The Most Advanced Fiber Optic Cable Blower
As a leader in the manufacture of cable installation tools and equipment, Condux offers a superior Fiber Optic Cable Blower that is compact and lightweight, making it ideally suited for your most difficult job sites.
Fast
Install fiber optic cable up to 300 fpm (100 mpm) (recommended 180-220 fpm (55-67 mpm)). A carrier can be attached to the front of the cable to help propel the fiber down an air-tight sealed duct. Because air flow and belt drive speed can be adjusted, you can install fiber at the rate which best suits your application.
Total Control
The Condux Gulfstream 400 Fiber Optic Cable Blower features a long belt grip area for less stress on the cable, and a manual cylinder on the belt feed to better control down pressure. Condux’s patented traction control system shuts down the blower when problems with cable slippage or duct blockage are detected, adding safety to every job and preventing costly cable damage.
A speed and distance counter with LCD read-out, as well as convenient hydraulic and pneumatic controls, come standard with the Condux Fiber Optic Cable Blower. Blowers equipped with the Advanced Electronic Control System will shut down if slippage, over-speed or cable stoppage are detected.
Versatility
The Condux Gulfstream 400 Fiber Optic Cable Blower operates efficiently with most common combinations of cable and innerduct sizes. The Condux Gulfstream 400 Fiber Optic Cable Blower is designed for the installation of fiber optic cables with diameters from 0.23″ (5.8 mm) to 1.13″ (28.7 mm) into micro duct 10 mm to 18 mm and traditional innerduct 1⁄2″ (13 mm) to 2″ (51 mm) with metric sizes available.
The correct size cable seals and venturi must be determined for the cable being installed. Also necessary are the correct size innerduct seals, clamps and carrier for the innerduct being occupied.
Industry Leading Features & Design
Advanced Electronic Controls
- Over pressure limit
- Slippage
- Cable stoppage
Smart Design, Easy to Operate
Convenient tilting of the Condux Gulfstream™ 400 Fiber Optic Cable Blower for ease of pouring in lubricant. Easily install cable into belt, then close and you are ready to start.
Hydraulic & pneumatic controls are ergonomically designed and conveniently located. No special maintenance is required.
Lightweight & Portable, Everything's Inside
The Condux Gulfstream™ 400 Fiber Optic Cable Blower is extremely easy to handle and transport. The blower and all accessories including hydraulic hoses, cable and conduit packs and seal kits conveniently fit into a lightweight job box with wheels.
Belt Drive
Single belt drive provides for smooth and quiet operation. The belt can be easily removed and replaced making maintenance fast and simple.
Condux Gulfstream™ Series Specification Chart
Blower Size
Dimensions:
Weight:
Duct Range
10mm – 51mm
½” – 2″
Fiber Cable Range
6mm – 28.7mm
0.25″ – 1.125″
Power System
Hydraulic Tractor Drive
Compressed Air
Drive
Belt Drive
Speed: 0-300ft/min fpm (0 – 100 mpm)
Maximum push force of 180lbs (778 N)
Features
- Speed and distance counter LCD read-out
- Hinged air block and conduit clamps
- Smooth and quiet belt tractor
- Emergency Stop Button
- Convenient tilt capability allowing ease of pouring in lubricant
- ECB prevents potential cable damage
Pressure and Flow
Air connections:
Air Pressure Requirements (BAR)*: 10-14
Air Pressure Requirements (PSI)*: 100-130
Flow Requirements (CFM)*: 185-500
Flow Requirements (CMM)*: 5-14
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.
Blower Size
Dimensions:
Weight: 325lbs (147 kg)
Job Box Size
2′ x 4’ (0.6m x 1.2m)
Duct Range
32mm – 63mm
1.25″ – 2″
Fiber Cable Range
12.5mm – 39mm
0.49″ – 1.54″
Power System
Hydraulic Tractor Drive
Compressed Air
Drive
Belt Drive
Speed: 0- fpm (0 – mpm)
Maximum push force 174lbs (778 N)
Features
- Speed and distance counter LCD read-out
- Hinged air block and conduit clamps
- Smooth and quiet belt tractor
- Emergency Stop Button
- ECB prevents potential cable damage
Pressure and Flow
Air connections:
Air Pressure Requirements (BAR)*: 7-10
Air Pressure Requirements (PSI)*: 100-150
Flow Requirements (CMM)*: 5 – 14
Flow Requirements (CFM)*: 185 – 500
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.
Blower Size
Dimensions: 23.6″ (l) x 13.9″ (w) x 13.1″ (h) – 599 mm (l) x 351 mm (w) x 331 mm (h)
Weight: 55 lbs/25 kg
Duct Range
0.50″ – 1.25″ (8mm – 42mm)
Fiber Cable Range
0.16″ – 0.65″ (4 mm – 16.5 mm)
Power System
Drive
Pneumatic Drive System
Maximum push force: 105 lbs. (467 N)
Dynamic Push Force: 70 lbs. @ 150 ft/min (312 N @ 45.7 m/min)
Features
- Electronic Counter/Real Time Distance (Feet and Meters)
- Speed Indicator (ft/min and m/min)
- No Tools Required for Belt Replacement
- Maximum Belt Visibility, Transparent Covers for Easy Monitoring
- Emergency Stop Button
- Air Conditioning: Filter, Regulator, and Lubricator
- Robust, Carrying Case
Air Compressor Requirements:
Microduct:
Maximum Air Pressure: 100 PSI (7 BAR)*
Recommended Air Pressure: 150-205 PSI (10-14 Bar)*
Minimum Flow Rating: 35 CFM (1.0 CMM)*
Traditional Duct:
Maximum Air Pressure: 100 PSI (7 BAR)*
Recommended Air Pressure: 115-150 PSI (7-10 Bar)*
Recommended Flow Rating: 185-375 CFM (5-11 CMM)*
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.
Dimensions: 11″ (l) x 8″ (w) x 6″ (h) – 279 mm (l) x 203 mm (w) x 152 mm (h)
Weight: 9 lbs/4.1 kg
Microduct Range
5mm – 18mm
0.197″ – 0.709″
Built in clamping system with interchangeable seals
Fiber Cable Range
2.5mm – 8 mm
0.098″ – 0.315″
Power System
Electric drive motor
48v AC Power Supply
(Plugged into wall or 1000 w Generator)
Drive
Belt drive
Maximum push force of 30 lbs (133 N)
Speed: 0-230 fpm (0 – 70mpm) with 48V inverter
Features
- Forward/reverse switch
- Speed control to regulate motor speed
- Emergency stop button for instant shutdown
- Screen that monitors speed, distance and life counter
- Push force adjustment
Pressure and Flow
Air connections: 3/8″ EU or US Coupling
Air Pressure Requirements (BAR)*: 10-15
Air Pressure Requirements (PSI)*: 150-205
Flow Requirements (CMM)*: 0.5-1.5
Flow Requirements (CFM)*: 10-35
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.
Blower Size
Dimensions: 11″ (l) x 8″ (w) x 6″ (h) – 279 mm (l) x 203 mm (w) x 152 mm (h)
Weight: 9 lbs/4.1 kg
Microduct Range
5mm – 18 mm
0.197″ – 0.709″
Built in clamping system with interchangeable seals
Fiber Cable Range
2.5mm – 8 mm
0.098″ – 0.315″
8.1 – 9.75mm (with specialty wheels, not included in kit)
Power System
Electric drive motor
48v AC Power Supply (Plugged into wall or 1000 w Generator)
Drive
Wheel drive
Maximum push force of 30 lbs (133 N)
Speed: 0-230 fpm (0 – 70 mpm) with 48V inverter
Features
- Forward/reverse switch
- Speed control to regulate motor speed
- Screen that monitors speed, distance and life counter
- Emergency stop button for instant shut down
- Push force adjustment
Pressure and Flow
Air connections: 3/8″ EU or US Coupling
Air Pressure Requirements (BAR)*: 10-15
Air Pressure Requirements (PSI)*: 150-205
Flow Requirements (CMM)*: 0.5-1.5
Flow Requirements (CFM)*: 10-35
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.
Blower Size
Dimensions: 8″ (l) x 6″ (w) x 6″ (h) – 203 mm (l) x 152 mm (w) x 152 mm (h)
Weight: 7 lbs/3.2 kg
Microduct Range
5 – 8 mm
0.197″ – 0.315″
Built in clamping system with interchangeable seals
Fiber Cable Range
1mm – 2.5 mm
0.049″ – 0.098″
Power System
Electric drive motor
12v (US) or 10.8v (EU) Cordless Battery (not included)
AC Power Supply (optional)
Drive
Roller Cover
Maximum push force of 4.5 lbs (20 N)
Speed: 0-375 fpm (0 – 115 mpm)
Features
- Screen that monitors speed and distance – life counter
- Forward/Reverse switch
- Speed control to regulate motor speed
- Push force adjustment
Pressure and Flow
Air connections: 1/4″ EU or US Coupling
Air Pressure Requirements (BAR)*: 10-15
Air Pressure Requirements (PSI)*: 150-205
Flow Requirements (CMM)*: 0.5-1.5
Flow Requirements (CFM)*: 10-35
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.