The Condux Gulfstream™ 400 Fiber Optic Cable Blower is designed for the installation of fiber optic cables with diameters from 0.23" (5.8 mm) to 1.13" (28.7 mm) into micro duct 10 mm to 18 mm and traditional innerduct ½" (13 mm) to 2" (51 mm) with metric sizes available. Install up to 300 feet of fiber optic cable per minute (90 m/min). The Gulfstream™ 400 features longer tractor feed grip area for less stress on the cable, and a manual cylinder on the tractor feed to better control down pressure.

The Condux Gulfstream™ 400 Fiber Optic Cable Blower is easy to order. The base unit comes complete with a job box, hydraulic hoses and everything listed below in the Common Parts Kit. Cable Packs and Duct Packs are included with every Gulfstream™ 400 Fiber Optic Cable Blower. You may order additional Cable Packs, Duct Packs, or Common Parts at any time.

Cable Packs (#1-7 included with base unit)
Cable Packs include Cable Grips (for end of cable), Pneumatic Venturies, and Cable Seals. See chart below for more information. Additional individual or replacement Cable Packs are also available.

Duct Packs (#2-6 included with base unit)
Duct Packs include Cable Grip (for end of innerduct), Cable Carrier, Innerduct Clamps, Innerduct Seals, Innerduct Pulling Eye & Foam Carriers. See chart below for more information. Additional individual or replacement Duct Packs are also available.

See Cable Packs, Duct Packs, and Common Parts
Select one item from any group and click “Add to Cart” or “Add to Quote.”  Need more items? Simply return here and repeat the process.

$0.00

$1.05

Blowing Up Fiber Installation

The Condux Gulfstream™ 400 is one of the originals when it comes to fiber optic cable blowing. There since the beginning, the Gulfstream™ 400 has installed more fiber optic cable than most people can even imagine. This piece of equipment helped change everything when it comes to fiber installation and helped feed the technology boom that has changed the way people live and work. It’s still doing that today. The Gulfstream™ 400 is a fiber installation powerhouse!

360° Product Viewer

gulfstream

Click and drag or swipe to view this product in 360°

Gulfstream™ 400
Gulfstream™ 400

The Most Advanced Fiber Optic Cable Blower

As a leader in the manufacture of cable installation tools and equipment, Condux offers a superior Fiber Optic Cable Blower that is compact and lightweight, making it ideally suited for your most difficult job sites.

Fast

Install fiber optic cable up to 300 fpm (100 mpm) (recommended 180-220 fpm (55-67 mpm)). A carrier can be attached to the front of the cable to help propel the fiber down an air-tight sealed duct. Because air flow and belt drive speed can be adjusted, you can install fiber at the rate which best suits your application.

Total Control

The Condux Gulfstream 400 Fiber Optic Cable Blower features a long belt grip area for less stress on the cable, and a manual cylinder on the belt feed to better control down pressure. Condux’s patented traction control system shuts down the blower when problems with cable slippage or duct blockage are detected, adding safety to every job and preventing costly cable damage.

A speed and distance counter with LCD read-out, as well as convenient hydraulic and pneumatic controls, come standard with the Condux Fiber Optic Cable Blower. Blowers equipped with the Advanced Electronic Control System will shut down if slippage, over-speed or cable stoppage are detected.

Versatility

The Condux Gulfstream 400 Fiber Optic Cable Blower operates efficiently with most common combinations of cable and innerduct sizes. The Condux Gulfstream 400 Fiber Optic Cable Blower is designed for the installation of fiber optic cables with diameters from 0.23″ (5.8 mm) to 1.13″ (28.7 mm) into micro duct 10 mm to 18 mm and traditional innerduct 1⁄2″ (13 mm) to 2″ (51 mm) with metric sizes available.

The correct size cable seals and venturi must be determined for the cable being installed. Also necessary are the correct size innerduct seals, clamps and carrier for the innerduct being occupied.

Industry Leading Features & Design

Gulfstream™ 400 Advanced Electronic Controls

Advanced Electronic Controls

Standard system monitors and displays the cable and belt drive speeds. When using traction control it will automatically shut off the blower in these conditions:

  • Over pressure limit
  • Slippage
  • Cable stoppage
Gulfstream™ 400

Smart Design, Easy to Operate

Convenient tilting of the Condux Gulfstream™ 400 Fiber Optic Cable Blower for ease of pouring in lubricant. Easily install cable into belt, then close and you are ready to start.

Hydraulic & pneumatic controls are ergonomically designed and conveniently located. No special maintenance is required.

Gulfstream™ 400

Lightweight & Portable, Everything's Inside

The Condux Gulfstream™ 400 Fiber Optic Cable Blower is extremely easy to handle and transport. The blower and all accessories including hydraulic hoses, cable and conduit packs and seal kits conveniently fit into a lightweight job box with wheels.

Gulfstream™ 400

Belt Drive

Single belt drive provides for smooth and quiet operation. The belt can be easily removed and replaced making maintenance fast and simple.

 

Condux Gulfstream™ Series Specification Chart

Blower Size
Dimensions:
Weight:

Duct Range
10mm – 51mm
½” – 2″

Fiber Cable Range
6mm – 28.7mm
0.25″ – 1.125″

Power System
Hydraulic Tractor Drive
Compressed Air

Drive
Belt Drive
Speed: 0-300ft/min fpm (0 – 100 mpm)
Maximum push force of 180lbs (778 N)

Features

  • Speed and distance counter LCD read-out
  • Hinged air block and conduit clamps
  • Smooth and quiet belt tractor
  • Emergency Stop Button
  • Convenient tilt capability allowing ease of pouring in lubricant
  • ECB prevents potential cable damage

Pressure and Flow
Air connections:

Air Pressure Requirements (BAR)*: 10-14
Air Pressure Requirements (PSI)*: 100-130

Flow Requirements (CFM)*: 185-500
Flow Requirements (CMM)*: 5-14

*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.

Blower Size
Dimensions:
Weight: 325lbs (147 kg)

Job Box Size
2′ x 4’ (0.6m x 1.2m)

Duct Range
32mm – 63mm
1.25″ – 2″

Fiber Cable Range
12.5mm – 39mm
0.49″ – 1.54″

Power System
Hydraulic Tractor Drive
Compressed Air

Drive
Belt Drive
Speed: 0- fpm (0 – mpm)
Maximum push force 174lbs (778 N)

Features

  • Speed and distance counter LCD read-out
  • Hinged air block and conduit clamps
  • Smooth and quiet belt tractor
  • Emergency Stop Button
  • ECB prevents potential cable damage

Pressure and Flow
Air connections:

Air Pressure Requirements (BAR)*: 7-10
Air Pressure Requirements (PSI)*: 100-150

Flow Requirements (CMM)*: 5 – 14
Flow Requirements (CFM)*: 185 – 500

*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.

Blower Size
Dimensions: 23.6″ (l) x 13.9″ (w) x 13.1″ (h) – 599 mm (l) x 351 mm (w) x 331 mm (h)
Weight: 55 lbs/25 kg

Duct Range
0.50″ – 1.25″ (8mm – 42mm)

Fiber Cable Range
0.16″ – 0.65″ (4 mm – 16.5 mm)

Power System

Drive
Pneumatic Drive System
Maximum push force: 105 lbs. (467 N)
Dynamic Push Force: 70 lbs. @ 150 ft/min (312 N @ 45.7 m/min)

Features

  • Electronic Counter/Real Time Distance (Feet and Meters)
  • Speed Indicator (ft/min and m/min)
  • No Tools Required for Belt Replacement
  • Maximum Belt Visibility, Transparent Covers for Easy Monitoring
  • Emergency Stop Button
  • Air Conditioning: Filter, Regulator, and Lubricator
  • Robust, Carrying Case

Air Compressor Requirements:

Microduct:
Maximum Air Pressure: 100 PSI (7 BAR)*
Recommended Air Pressure: 150-205 PSI (10-14 Bar)*
Minimum Flow Rating: 35 CFM (1.0 CMM)*

Traditional Duct:
Maximum Air Pressure: 100 PSI (7 BAR)*
Recommended Air Pressure: 115-150 PSI (7-10 Bar)*
Recommended Flow Rating: 185-375 CFM (5-11 CMM)*

*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.

Blower Size
Dimensions: 11″ (l) x 8″ (w) x 6″ (h) – 279 mm (l) x 203 mm (w) x 152 mm (h)
Weight: 9 lbs/4.1 kg

Microduct Range
5mm – 18mm
0.197″ – 0.709″
Built in clamping system with interchangeable seals

Fiber Cable Range
2.5mm – 8 mm
0.098″ – 0.315″

Power System
Electric drive motor
48v AC Power Supply
(Plugged into wall or 1000 w Generator)

Drive
Belt drive
Maximum push force of 30 lbs (133 N)
Speed: 0-230 fpm (0 – 70mpm) with 48V inverter

Features

  • Forward/reverse switch
  • Speed control to regulate motor speed
  • Emergency stop button for instant shutdown
  • Screen that monitors speed, distance and life counter
  • Push force adjustment

Pressure and Flow
Air connections: 3/8″ EU or US Coupling

Air Pressure Requirements (BAR)*: 10-15
Air Pressure Requirements (PSI)*: 150-205

Flow Requirements (CMM)*: 0.5-1.5
Flow Requirements (CFM)*: 10-35

*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.

Blower Size
Dimensions: 11″ (l) x 8″ (w) x 6″ (h) – 279 mm (l) x 203 mm (w) x 152 mm (h)
Weight: 9 lbs/4.1 kg

Microduct Range
5mm – 18 mm
0.197″ – 0.709″
Built in clamping system with interchangeable seals

Fiber Cable Range
2.5mm – 8 mm
0.098″ – 0.315″

8.1 – 9.75mm (with specialty wheels, not included in kit)

Power System
Electric drive motor
48v AC Power Supply (Plugged into wall or 1000 w Generator)

Drive
Wheel drive
Maximum push force of 30 lbs (133 N)
Speed: 0-230 fpm (0 – 70 mpm) with 48V inverter

Features

  • Forward/reverse switch
  • Speed control to regulate motor speed
  • Screen that monitors speed, distance and life counter
  • Emergency stop button for instant shut down
  • Push force adjustment

Pressure and Flow
Air connections: 3/8″ EU or US Coupling

Air Pressure Requirements (BAR)*: 10-15
Air Pressure Requirements (PSI)*: 150-205

Flow Requirements (CMM)*: 0.5-1.5
Flow Requirements (CFM)*: 10-35

*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.

Blower Size
Dimensions: 8″ (l) x 6″ (w) x 6″ (h) – 203 mm (l) x 152 mm (w) x 152 mm (h)
Weight: 7 lbs/3.2 kg

Microduct Range
5 – 8 mm
0.197″ – 0.315″
Built in clamping system with interchangeable seals

Fiber Cable Range
1mm – 2.5 mm
0.049″ – 0.098″

Power System
Electric drive motor
12v (US) or 10.8v (EU) Cordless Battery (not included)
AC Power Supply (optional)

Drive
Roller Cover
Maximum push force of 4.5 lbs (20 N)
Speed: 0-375 fpm (0 – 115 mpm)

Features

  • Screen that monitors speed and distance – life counter
  • Forward/Reverse switch
  • Speed control to regulate motor speed
  • Push force adjustment

Pressure and Flow
Air connections: 1/4″ EU or US Coupling

Air Pressure Requirements (BAR)*: 10-15
Air Pressure Requirements (PSI)*: 150-205

Flow Requirements (CMM)*: 0.5-1.5
Flow Requirements (CFM)*: 10-35

*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.

Ordering Information

Part NumberDescription
08782005Gulfstream™ 400 Fiber Optic Cable Blower w/Electronic Control Box
08782006Gulfstream™ 400 Fiber Optic Cable Blower w/Mechanical Control Box
Cable Packs
08780393Cable Pack #1 0.23-0.34 in (5.8-8.8 mm)
08780394Cable Pack #2 0.35-0.48 in (8.9-12.2 mm)
08780512Cable Pack #3 0.49-0.60 in (12.4-15.2mm)
08780395Cable Pack #4 0.61-0.73 in (15.3-18.5 mm)
08780513Cable Pack #5 0.74-0.85 in (18.8-21.6mm)
08780396Cable Pack #6 0.86-0.97 in (22.0-24.5 mm)
08780514Cable Pack #7 0.98-1.13 in (24.9-28.7mm)
08781117Cable Pack #8 10.4 x 5.5 mm (Nylatron Venturi for flat fiber cables)Â
08781118Cable Pack #9 15.2 x 6.7 mm (Nylatron Venturi for flat fiber cables)
Duct Packs
08780795Duct Pack #1 - 0.5" SDR 11/13.5
08780680Duct Pack #2 - 0.75" SDR 11/13.5
08780386Duct Pack #3 - 1" SDR 11/13.5
08780392Duct Pack #4 - 1.25" SDR 11/13.5
08780397Duct Pack #5 - 1.5" SDR 11/13.5
08780930Duct Pack #6 - 2" SDR 11/13.5
08781120Duct Pack #7 - 20 mm
08781153Duct Pack #8 - 22mm
08780240Duct Pack #9 - 25 mm
08780385Duct Pack #10 - 32mm
08780387Duct Pack #11 - 36 mm
08780388Duct Pack #12 - 37 mm
08780389Duct Pack #13 - 1.25" TRUE
08780390Duct Pack #14 - 40 mm
08780391Duct Pack #15 - 42 mm
08780545Duct Pack #16 - 44 mm
08780575Duct Pack #17 - 50 mm
Common Parts Kit
02290222Small Case
08780506Foam Insert for Small Case
02284600Small Divided Case
02288774Parts Label for Small Divided Case
08780126O-Ring Seal Kit
022864162 Pin Extension Cord
08230800Canvas Bag
080170005/8" x 600lb Swivel (16mm x 2,669N)
08780424Capscrew Set (12-M04-07)
022896203/4" Wrench
02290168Standard and Metric Hex Key Set
022838003/32" Hex Ball Driver
022887872.5mm Hex Ball Point Driver
022910909/16" Comb-Ratchet Wrench
08781170Venturi Air Plug (Seal Disk)
Other
08761248Power Cord Assembly Lighter Plug (No longer included in common parts kit; Sold Separately)


Blower Size Overview

Cable ODDuct Size
MillimetersInchesMillimetersInches
Condux Fiber BlowerMinMaxMinMaxMinMaxMinMax
GS 15012.50.0490.098580.1970.315
GS 2502.580.0980.3155180.1970.709
GS 3002.580.0980.3155180.1970.709
GS 350+416.50.160.658420.51.25
Mini-Blower/Pusher5.812.70.230.510(M) or 12.7(T)18(M) or 50.8(T)0.52
GS 400628.70.251.12510500.3982
GS 400XL12.5390.491.5432631.252