Blower Size
Dimensions: 8″ (l) x 6″ (w) x 6″ (h) – 203 mm (l) x 152 mm (w) x 152 mm (h)
Weight: 7 lbs/3.2 kg
Microduct Range
5 – 8 mm
0.197″ – 0.315″
Built in clamping system with interchangeable seals
Fiber Cable Range
1mm – 2.5 mm
0.049″ – 0.098″
Power System
Electric drive motor
12v (US) or 10.8v (EU) Cordless Battery (not included)
AC Power Supply (optional)
Drive
Roller Cover
Maximum push force of 4.5 lbs (20 N)
Speed: 0-375 fpm (0 – 115 mpm)
Features
- Screen that monitors speed and distance – life counter
- Forward/Reverse switch
- Speed control to regulate motor speed
- Push force adjustment
Pressure and Flow
Air connections: 1/4″ EU or US Coupling
Air Pressure Requirements (BAR)*: 10-15
Air Pressure Requirements (PSI)*: 150-205
Flow Requirements (CMM)*: 0.5-1.5
Flow Requirements (CFM)*: 10-35
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.
Blower Size
Dimensions:
Weight:
Duct Range
10mm – 51mm
½” – 2″
Fiber Cable Range
6mm – 28.7mm
0.25″ – 1.125″
Power System
Hydraulic Tractor Drive
Compressed Air
Drive
Belt Drive
Speed: 0-300ft/min fpm (0 – 100 mpm)
Maximum push force of 180lbs (778 N)
Features
- Speed and distance counter LCD read-out
- Hinged air block and conduit clamps
- Smooth and quiet belt tractor
- Emergency Stop Button
- Convenient tilt capability allowing ease of pouring in lubricant
- ECB prevents potential cable damage
Pressure and Flow
Air connections:
Air Pressure Requirements (BAR)*: 10-14
Air Pressure Requirements (PSI)*: 100-130
Flow Requirements (CFM)*: 185-500
Flow Requirements (CMM)*: 5-14
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.
Blower Size
Dimensions:
Weight: 325lbs (147 kg)
Job Box Size
2′ x 4’ (0.6m x 1.2m)
Duct Range
32mm – 63mm
1.25″ – 2″
Fiber Cable Range
12.5mm – 39mm
0.49″ – 1.54″
Power System
Hydraulic Tractor Drive
Compressed Air
Drive
Belt Drive
Speed: 0- fpm (0 – mpm)
Maximum push force 174lbs (778 N)
Features
- Speed and distance counter LCD read-out
- Hinged air block and conduit clamps
- Smooth and quiet belt tractor
- Emergency Stop Button
- ECB prevents potential cable damage
Pressure and Flow
Air connections:
Air Pressure Requirements (BAR)*: 7-10
Air Pressure Requirements (PSI)*: 100-150
Flow Requirements (CMM)*: 5 – 14
Flow Requirements (CFM)*: 185 – 500
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.
Blower Size
Dimensions: 23.6″ (l) x 13.9″ (w) x 13.1″ (h) – 599 mm (l) x 351 mm (w) x 331 mm (h)
Weight: 55 lbs/25 kg
Duct Range
0.50″ – 1.25″ (8mm – 42mm)
Fiber Cable Range
0.16″ – 0.65″ (4 mm – 16.5 mm)
Power System
Drive
Pneumatic Drive System
Maximum push force: 105 lbs. (467 N)
Dynamic Push Force: 70 lbs. @ 150 ft/min (312 N @ 45.7 m/min)
Features
- Electronic Counter/Real Time Distance (Feet and Meters)
- Speed Indicator (ft/min and m/min)
- No Tools Required for Belt Replacement
- Maximum Belt Visibility, Transparent Covers for Easy Monitoring
- Emergency Stop Button
- Air Conditioning: Filter, Regulator, and Lubricator
- Robust, Carrying Case
Air Compressor Requirements:
Microduct:
Maximum Air Pressure: 100 PSI (7 BAR)*
Recommended Air Pressure: 150-205 PSI (10-14 Bar)*
Minimum Flow Rating: 35 CFM (1.0 CMM)*
Traditional Duct:
Maximum Air Pressure: 100 PSI (7 BAR)*
Recommended Air Pressure: 115-150 PSI (7-10 Bar)*
Recommended Flow Rating: 185-375 CFM (5-11 CMM)*
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.
Dimensions: 11″ (l) x 8″ (w) x 6″ (h) – 279 mm (l) x 203 mm (w) x 152 mm (h)
Weight: 9 lbs/4.1 kg
Microduct Range
5mm – 18mm
0.197″ – 0.709″
Built in clamping system with interchangeable seals
Fiber Cable Range
2.5mm – 8 mm
0.098″ – 0.315″
Power System
Electric drive motor
48v AC Power Supply
(Plugged into wall or 1000 w Generator)
Drive
Belt drive
Maximum push force of 30 lbs (133 N)
Speed: 0-230 fpm (0 – 70mpm) with 48V inverter
Features
- Forward/reverse switch
- Speed control to regulate motor speed
- Emergency stop button for instant shutdown
- Screen that monitors speed, distance and life counter
- Push force adjustment
Pressure and Flow
Air connections: 3/8″ EU or US Coupling
Air Pressure Requirements (BAR)*: 10-15
Air Pressure Requirements (PSI)*: 150-205
Flow Requirements (CMM)*: 0.5-1.5
Flow Requirements (CFM)*: 10-35
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.
Blower Size
Dimensions: 11″ (l) x 8″ (w) x 6″ (h) – 279 mm (l) x 203 mm (w) x 152 mm (h)
Weight: 9 lbs/4.1 kg
Microduct Range
5mm – 18 mm
0.197″ – 0.709″
Built in clamping system with interchangeable seals
Fiber Cable Range
2.5mm – 8 mm
0.098″ – 0.315″
8.1 – 9.75mm (with specialty wheels, not included in kit)
Power System
Electric drive motor
48v AC Power Supply (Plugged into wall or 1000 w Generator)
Drive
Wheel drive
Maximum push force of 30 lbs (133 N)
Speed: 0-230 fpm (0 – 70 mpm) with 48V inverter
Features
- Forward/reverse switch
- Speed control to regulate motor speed
- Screen that monitors speed, distance and life counter
- Emergency stop button for instant shut down
- Push force adjustment
Pressure and Flow
Air connections: 3/8″ EU or US Coupling
Air Pressure Requirements (BAR)*: 10-15
Air Pressure Requirements (PSI)*: 150-205
Flow Requirements (CMM)*: 0.5-1.5
Flow Requirements (CFM)*: 10-35
*Air pressure and flow requirements depend on the size of duct and the size of fiber being installed into that duct.